Derived Parameters
Standard Parameters
The following table presents the derived parameters. These calculations are hard coded, and are calculated before the Formula Tool.
DGD Field Name | Caption | Symbol | Unit | Description |
---|---|---|---|---|
Penetration_Rate | Rate calculated based on Time_Elapsed and Depth | |||
Bulk_Unit_Weight | Bulk Unit Weight | γ_b | kN⁄m^3 | Bulk unit weight, γ_b, the calculation source is defined on Project Parameters and Point Parameters:
|
In_Situ_Pore_Pressure | In Situ u | u_o | kPa | In situ pore pressure, u_o, refer to section Groundwater and Over water Testing for a full explanation. |
Excess_Pore_Pressure | Delta u | \Delta u | kPa | Excess pore pressure, ∆u =u_2 - u_o |
Normalised_Excess_Pore_Pressure | Normalised Delta u | Normalised \Delta u | Normalised excess pore pressure, normalised ∆u =\frac{ u_2 - u_o}{\sigma'_{vo}} | |
Slope_Indicator | Inclination | \alpha | deg | Non-directional inclinometer measured value, or calculated from \alpha={\sqrt{\beta_{1}^2+\beta_{2}^2}} |
Total_Stress | Total Stress | σ_{vo} | kPa | In situ total vertical stress, σ_{vo}=\sum^{n}_{i=1} \gamma_{bi} \Delta z_i |
Effective_Stress | Effective Stress | σ'_{vo} | kPa | In situ effective vertical stress, \sigma'_{vo}=σ_{vo}-u_o |
Total_Cone_Resistance | qt | q_t | MPa | Total cone resistance, |
Total_Cone_Resistance_Moving_Average | Moving Average qt | MPa | Moving average qt over distance defined on CPT_PROJECT_PARAMETERS | |
Total_Cone_Resistance_Moving_Average_Inc | Moving Average qt Included | MPa | Moving average qt that are not excluded over distance defined on CPT_PROJECT_PARAMETERS | |
Net_Cone_Resistance | qn | q_n | MPa | Net cone resistance, |
Corrected_Sleeve_Friction | ft | f_t | kPa | Sleeve friction corrected for pore pressure effects, f_t = f_s - \frac{(u_2 \cdot A_{sb} - u_3 \cdot A_{st})}{A_s} |
Friction_Ratio | Rf | R_f | % | Friction ratio: R_f = \frac{f_t}{q_t}\cdot 100, R_f = \frac{f_s}{q_t}\cdot 100, or R_f = \frac{f_s}{q_c}\cdot 100 |
Normalised_Friction_Ratio | Fr | F_r | % | Normalised friction ratio, |
Normalised_Cone_Resistance | Qt | Q_t | - | Normalised cone resistance, Q_t = \frac{(q_t-\sigma_{v0})}{\sigma'_{v0}} |
Stress_Normalised_Cone_Resistance | qt1 | q_{t1} | - | Stress normalised cone resistance (Kulhawy and Mayne 1990, Jamiolkowski et al 2001), q_{t1}=\frac{q_t}{\sqrt{\sigma'_{v0}\cdot\sigma_{atm}}} |
Pore_Pressure_Ratio | Bq | B_q | - | Pore pressure ratio, B_q= \frac{\Delta u}{(q_t-\sigma_{v0})} |
Differential_Pore_Pressure_Ratio | DPPR | DPPR | - | Differential pore pressure ratio, DPRR= \frac{\Delta u}{q_t} |
Dimensionless_Penetration_Resistance | Qt(1-Bq)+1 | Q_t(1-B_q )+1 | - | Dimensionless penetration resistance |
Begemann Mechanical Cone Calculations
In case of using a Begemann mechanical subtraction cone, the corrected values for q_c and f_s are calculated from input data cone readings 1 and 2 as:
q_c = M_1 \cdot \frac{ A_p}{A_c} +W_1+W_2 \cdot n\\ \ \\ \text{Or if one of }M_1, A_p, A_c, W_1 \text{ or }W_2 \text{ is NULL:} \quad q_c = M_1 |
f_s = (M_{2\text{, row i+1}}-M_{1\text{, row i+1}} ) \cdot A_p/A_s |
TF = \sum f_s \cdot (z_i - z_{i-1}) |
Where:
M_1 is the mechanical cone reading 1 and is taken from Mechanical_Reading_1 field, for f_s values from the next row are used
M_2 is the mechanical cone reading 2 and is taken from Mechanical_Reading_2 field, for f_s values from the next row are used
A_p is the area of plunger and is taken from Area_Plunger field on CPT_CONE_INFORMATION
A_c is the projected area of the cone and is taken from Area_Cone field on CPT_CONE_INFORMATION
W_1 is the mass of cone and is taken from Mass_Cone field on CPT_CONE_INFORMATION
W_2 is the mass of cone inner rod and is taken from Mass_Inner_Rod field on CPT_CONE_INFORMATION
n is the number of rods used, calculated from dividing Depth by Length_Inner_Rod on CPT_CONE_INFORMATION, rounded up to nearest whole number plus one if the top of the rod is at the ground surface
A_s is the area of sleeve and is taken from Area_Friction_Casing field on CPT_CONE_INFORMATION
TF is the Total Sleeve Friction Resistance
Friction Ratio Calculation Method
The field Friction_Ratio_Calculation_Method on CPT_PROJECT_PARAMETERS defines the method of calculation. The options are:
- qt or qc on same row as fs: All data is taken form the same row, this is the default
- Average qt or qc over sleeve: Uses average (arithmetic mean) qt or qc over range of sleeve