Particle Size Distribution

Sieve

Supported Test Methods

Standard

Description

ASTM C 136-06

Sieve analysis of fine and coarse grained aggregates

ASTM D 422-63

Particle size analysis of soils

BS1377-2:1990:9.2

Determination of particle size distribution - wet sieve method

BS1377-2:1990:9.3

Determination of particle size distribution - dry sieve method

BS812-103:1985:7.2

Particle size distribution - washing and sieving method

BS812-103:1985:7.3

Particle size distribution - dry sieving method

ISO/TS 17892-4:2004 5.2

Determination of particle size distribution - Sieving.

Input

Lab-Class | Sieve

To calculate the particle size distribution of a specimen, you must first select the standard from the Test_Method field on the Sieve (upper) table that the specimen is being tested against. Once selected, click Save and the necessary data entry fields will be automatically highlighted to assist you in entering the relevant data for the selected test method. Specify in the Data_Type field if your data is from a Cumulative or an Incremental test

Enter the test data in the data entry fields on the Sieve (lower) table for each sieve size and when you change table or select save, the PSD values will be calculated automatically and the result will be displayed in the calculated fields.

Output

  • Graph Report | A L CS PSD 10 PER PAGE SUMMARY
  • Graph Report | A L CS PSD 20 PER PAGE SUMMARY
  • Graph Report | A L CS PSD ENVELOPE SUMMARY
  • Graph Report | L CS PSD ASTM
  • Graph Report | L CS PSD BSI
  • Histogram Report | A L CS PSD FINES CONTENT

Sedimentation by Hydrometer

Hydrometer Calibration

Lab-Class | Hydrometer Calibration

Complete the data entry fields and enter any other associated metadata as required. The value entered in the Hydrometer_ID field will then be used in the lookup list in the Hydrometer_ID field on the Sedimentation table.

Supported Test Methods

Standard

Description

ASTM D 422-63

Particle size analysis of soils

BS1377-2:1990:9.5

Determination of particle size distribution – sedimentation by the hydrometer method

ISO/TS 17892-4:2004:5.3

Determination of particle size distribution – Hydrometer

Input

Lab-Class | Sedimentation

To calculate the particle size distribution of a specimen, you must first select the standard from the Test_Method field on the Sedimentation (upper) table that the specimen is being tested against. Once selected, click Save and the necessary data entry fields will be automatically highlighted to assist you in entering the relevant data in the Sedimentation (upper) table for the selected test method.



Enter the test data in the data entry fields on the Sedimentation (lower) table for each reading and when you change table or select save, the values will be calculated automatically and the result will be displayed in the calculated fields.

The following examples show the required fields in the lower table for each selected standard.

Sedimentation by Hydrometer Readings – ASTM D 422-63

Sedimentation by Hydrometer Readings – BS1377-2:1990:9.5

Sedimentation by Hydrometer Readings – ISO/TS 17892-4:2004:5.3

Output

  • Graph Report | A L CS PSD 10 PER PAGE SUMMARY
  • Graph Report | A L CS PSD 20 PER PAGE SUMMARY
  • Graph Report | A L CS PSD ENVELOPE SUMMARY
  • Graph Report | L CS PSD ASTM
  • Graph Report | L CS PSD BSI
  • Histogram Report | A L CS PSD FINES CONTENT
On this page