Fence Reports

Reports

Name

Description

CPT FENCE 11X17L

A3 landscape fence report with 6 plot column options and CPT classification colour column

CPT FENCE A3L

A3 landscape fence report with 6 plot column options and CPT classification colour column

CPT FENCE A3L NO GRID LINES

A3 landscape fence report with 6 plot column options and CPT classification colour column without grid lines

CPT FENCE A4L

A4 landscape fence report with 6 plot column options and CPT classification colour column

CPT FENCE A4P

A4 portrait fence report with 6 plot column options and CPT classification colour column

CPT FENCE LETL

Letter landscape fence report with 6 plot column options and CPT classification colour column

CPT FENCE LETP

Letter portrait fence report with 6 plot column options and CPT classification colour column

User Report Variables

Name

Default Value

Notes

Title

Inferred Subsurface Section

Enter fence report title

Drawn


Person's initials/name

Drawn Date


Enter date

Checked


Person's initials/name

Checked Date


Enter date

Figure Number


Enter text. If left blank, it will default to "Figure 1".

Revision


Enter Revision

Sheet


Enter Sheet

Override Sitemap Scale


Enter a value to override the default sitemap scale

Stick CPT

C

C = Soil classification method colour (default)
L = Legend/material graphic
L C = Legend/ Soil classification method colour
S = Stick/line

Default Title


Enter default fence report title. Shown if Title is empty.

Column R3


Enter a parameter to display on the right side of the fence post, furthest from the centre of the PointID

Width R3 (mm)


Enter the column width of the parameter. If left blank, it will use the default column width defined for that parameter. Typical values are 10 mm for line and bar plots, 4 mm for text

Column R2


Enter a parameter to display on the right side of the fence post

Width R2 (mm)


Enter the column width of the parameter. If left blank, it will use the default column width defined for that parameter. Typical values are 10 mm for line and bar plots, 4 mm for text

Column R1


Enter a parameter to display on the right side of the fence post, closest to the centre of the PointID

Width R1 (mm)


Enter the column width of the parameter. If left blank, it will use the default column width defined for that parameter. Typical values are 10 mm for line and bar plots, 4 mm for text

Column L1


Enter a parameter to display on the left side of the fence post, closest to the centre of the PointID

Width L1 (mm)


Enter the column width of the parameter. If left blank, it will use the default column width defined for that parameter. Typical values are 10 mm for line and bar plots, 4 mm for text

Column L2


Enter a parameter to display on the left side of the fence post

Width L2 (mm)


Enter the column width of the parameter. If left blank, it will use the default column width defined for that parameter. Typical values are 10 mm for line and bar plots, 4 mm for text

Column L3


Enter a parameter to display on the left side of the fence post, furthest from the centre of the PointID

Width L3 (mm)


Enter the column width of the parameter. If left blank, it will use the default column width defined for that parameter. Typical values are 10 mm for line and bar plots, 4 mm for text

Legend 1


Enter a parameter to display a legend for the line, colour, data marker and reference text for each correlation of that parameter

Legend 2


Enter a parameter to display a legend for the line, colour, data marker and reference text for each correlation of that parameter

Legend 3


Enter a parameter to display a legend for the line, colour, data marker and reference text for each correlation of that parameter

Legend 4


Enter a parameter to display a legend for the line, colour, data marker and reference text for each correlation of that parameter

Adding the CPT Tool fence stick to a non-CPT Tool fence report

If you have the DGD Tool or Fence and Map Tool, then:

  1. Navigate to Fence Blocks, select Blocks > Replace Block Names, replace DG STICK with DG STICK HYBRID.
  2. Then go to fence block DG STICK HYBRID and change the block reference from DG STICK HYBRID to DG STICK.
  3. Go to a REPORT DESIGN | Fence, and open CPT FENCE A3L.
  4. Select File > Page > Copy Report Variables, and then select all lines from Width 3 down to bottom of list. Click OK.
  5. Select the reports you want to merge to, and click OK.

If you don't have the DGD Tool or Fence and Map Tool, then this may be achieved by referencing the Fence Block Int!dg cpt stick. You may like to apply the following code to the Block Properties Output Condition to ensure the CPT Tool columns don't print for non-CPT PointIDs: <<CBool(<<Count(<<CPT_DATA.Depth>>)>>)>>

On this page