Lugeon Water Test
Introduction
IS-Other | Lugeon Water Test
The Lugeon Water test uses the analysis methods defined in Houlsby (1976) and the calculation is designed to support two different readings methods: Fixed Time and Fixed Volume.
You must first select the method from the Reading_Method field on the Lugeon_Water_Test (upper) table. Once saved, the data entry fields will be automatically coloured to assist you ring the relevant data in the Lugeon_Water_Test (upper) and Lugeon_Water_Test_Readings (lower) tables for the selected Reading_Method.
In order to allow the user to override the calculation for the reported result, the Lugeon_Value needs to be empty for the Lugeon_Value and Hydraulic_Conductivity fields to calculate.
Data Entry Procedure by Fixed Time
The Datgel Advanced In Situ Tool allows you to choose between two options for the reading intervals: 'Fixed Time 1 min' and 'Fixed Time 5 min'.
Fixed Time 1 min - Low volume tests, record volume for fixed 1 min intervals
- Enter the Depth, Bottom, Test_Number, Borehole_Diameter, Packer_Type, Packer_Inflation_Pressure, Packer_Inflation_Pressure_Remark, Friction_Losses, Packer_Seal, Pressure_Gauge_Height, Initial Groundwater_Depth, and the Flow_Type fields in the upper table.
- When you change table row or click save (Ctrl+S), the Initial_Groundwater_Depth_bgl, Depth_bgl, Centre_bgl, Bottom_bgl, Test_Length and Correction_Gauge_Pressure fields will also be automatically written to the Lugeon_Water_Test (upper) table.
- Enter the Test_Pressure, Flow_Meter_Reading_Start, Flow_Meter_Reading_Start, Flow_Meter_Reading_2_min a,Flow_Meter_Reading_3_min, Flow_Meter_Reading_4_min, ... etc fields in the lower table. You need to populate only the needed fields. Click save or Ctrl+S and the Volume_0-1_min, Volume_1-2_min, Volume_2-3_min, ..., Effective_Head, Volume_Loss, Flow_Rate, Flow_Rate_Per_Metre, Lugeon_Value and Hydraulic_Conductivity fields in the lower table and the Average_Lugeon_Value, Average_Hydraulic_Conductivity, Lugeon_Value and Hydraulic_Conductivity in the upper table will be automatically calculated.
- You may set the Flow_Type, Lugeon_Sign and Lugeon_Value in the upper table according your interpretation.
If you need to change the value on Flow_Type, first you need to remove the data stored in Lugeon_Value and Hydraulic_Conductivity before recalculate.
Fixed Time 5 min - Low volume tests, record volume for fixed 5 min intervals
- Enter the Depth, Bottom, Test_Number, Borehole_Diameter, Packer_Type, Packer_Inflation_Pressure, Packer_Inflation_Pressure_Remark, Friction_Losses, Packer_Seal, Pressure_Gauge_Height, Initial Groundwater_Depth, and the Flow_Type fields in the upper table.
- When you change table row or click save (Ctrl+S), the Initial_Groundwater_Depth_bgl, Depth_bgl, Centre_bgl, Bottom_bgl, Test_Length and Correction_Gauge_Pressure fields will also be automatically written to the Lugeon_Water_Test (upper) table.
- Enter the Test_Pressure, Flow_Meter_Reading_Start, Flow_Meter_Reading_5_min, Flow_Meter_Reading_10_min and the Flow_Meter_Reading_15_min fields in the lower table. Click save or Ctrl+S and the Volume_0-5_min, Volume_5-10_min, Volume_10-15_min, Effective_Head, Volume_Loss, Flow_Rate, Flow_Rate_Per_Metre, Lugeon_Value and Hydraulic_Conductivity fields in the lower table and the Average_Lugeon_Value, Average_Hydraulic_Conductivity, Lugeon_Value and Hydraulic_Conductivity in the upper table will be automatically calculated.
- You may change the Flow_Type, Lugeon_Sign and Lugeon_Value in the upper table according your interpretation.
If you need to change the value on Flow_Type, first you need to remove the data stored in Lugeon_Value and Hydraulic_Conductivity before recalculate.
Data Entry Procedure by Fixed Volume - High volume tests, record time for fixed volume
- Enter the Depth, Bottom, Test_Number, Borehole_Diameter, Fixed_Volume, Packer_Type, Packer_Inflation_Pressure, Packer_Inflation_Pressure_Remark, Friction_Losses, Packer_Seal, Pressure_Gauge_Height, Initial_Groundwater_Depth, and the Flow_Type fields in the upper table.
- When you change table, row or click save (Ctrl+S), the Initial_Groundwater_Depth _ bgl, Depth_bgl, Centre_bgl, Bottom_bgl, Test_Length and Correction_Gauge_Pressure fields will also be automatically written to the Lugeon_Water_Test (upper) table.
- Enter the Test_Pressure, Elapsed_Time_1, Elapsed_Time_2 and the Elapsed_Time_3 fields in the lower table. You may leave 2, or 2 and 3 empty. Each interval is the time for the given Fixed Volume to flow. The average is used to calculate flow rate.
- Click save (Ctl+S) and the Effective_Head, Volume_Loss, Flow_Rate, Flow_Rate_Per_Metre, Lugeon_Value and Hydraulic_Conductivity fields in the lower table and the Average_Lugeon_Value, Average_Hydraulic_Conductivity, Lugeon_Value and Hydraulic_Conductivity in the upper table will be automatically calculated.
- You may change the Flow_Type, Lugeon_Sign and Lugeon_Value in the upper table according your interpretation.
If you need to change the value on Flow_Type, first you need to remove the data stored in Lugeon_Value and Hydraulic_Conductivity before recalculate.
Analysis
The calculation of the Lugeon_Value and Hydraulic_Conductivity for the selected Flow_Type is calculated according to Houlsby 1976 interpretation:
- Laminar Flow: Uses the average of Lugeon Value and the average of the Hydraulic Conductivity.
- Turbulent Flow: Uses the Lugeon Value for the highest pressure.
- Dilation: Uses the Lugeon for the lowest (or medium) pressures.
- Wash-out: Uses the Highest Lugeon Value.
- Void Filling: Uses the final Lugeon value.
Output
- Graph | AST LUGEON WATER TEST